The Spark One real retrofit, surveyed twice. Worked the old way, the house needed a heat pump around 30% larger than the way the standard now requires. Nothing about the building changed. What changed, in January, was how the industry counts the heat that leaves your house in the air rather than through the walls. Around 93% of British homes were built before 2000. Those are the ones the old method treated most harshly, and the number it produces decides the size of the heat pump you get quoted for. |
|||||||||||
|
This Week in Watts Two kinds of draught, only one of them is worth paying to stopA house loses heat two ways. Through the fabric, conducting out through walls, roof, windows and floor. And through air, warm air leaving and cold air arriving to replace it. Everyone talks about the first. Almost nobody shows you the second. Split the air half and it gets useful. Some is uncontrolled infiltration: draughts around frames, an open chimney, unsealed floorboards. Nobody designed those. The rest is deliberate ventilation through trickle vents and extract fans, and it exists because a house with no air exchange gets damp and unhealthy. The standard states a minimum of half an air change an hour in habitable rooms, because anyone sitting in a stuffy room opens a window and undoes the lot. The leaky half is where the easy money sits. Failed sealant around window and door frames is the most common thing I find, and the fix is a tube of sealant rather than a project. Extract fans are next. The duct wants sealing where it passes through the wall, and there should be a cover outside with a flap that shuts when the fan is off. Without one you have left a hole in your wall with a breeze coming down it. Until this year the calculation treated both with a guess. Each room got an air change rate from a table, by room type and roughly when the house was built. The CIBSE Domestic Heating Design Guide 2026, published in January, moved away from those defaults, and MCS took its figures from BS EN 12831-1:2017 instead. The replacement starts with the building: how leaky the structure is, then how much of each room has an external wall. Party walls are disconted, because there is a heated space next door. Chimneys and extract fans go back in, since a pressure test blocks them off.
That is one room on the coldest day of the year, not an annual bill. Anyone turning a heat loss figure straight into yearly savings is selling something. OpenEnergyMonitor, who publish monitored data from real installations rather than models, report the compliant calculation effectively halves ventilation losses in pre-2000 naturally ventilated buildings. One caveat: that halving applies when rooms are combined to size the heat pump. Radiators are still sized on each room's own figure. Then the money. Oversize a heat pump and it cycles, switching on and off because it cannot modulate below what the house needs on a mild day. Spruce is blunt: shorter compressor life, lower SCOP, higher running costs. Size the radiators to match an overstated demand and you specify triple-panel radiators throughout, which Spruce says is where a lot of these projects die at proposal stage. A little oversizing, 10 to 15%, does beat undersizing. This is not that. This is a number nobody measured.
|
|||||||||||
|
The Bill Buster
|
|||||||||||
|
Watts on the Market
|
|||||||||||
|
Quick Watts Heat pump installs 20,895 heat pumps went into existing UK homes in the first half of 2026, down 22% on the 26,768 a year earlier. The government's ambition is 450,000 a year by 2030. DESNZ classes the series as still in development. Capacity market DESNZ is consulting on how Demand Side Response is de-rated, proposing either a duration-based or a technology-based method. It closes on 27 October. Worth a look if you have flexible load or storage earning capacity payments. |